Installation



I&M


?








Contents
1 - INTRODUCTION............................................................................................................ 1
2 - INSTALLATION ............................................................................................................. 1
Installer Requirements................................................................................................................. 1
Required Materials ..................................................................................................................................................1
Installation Overview.................................................................................................................... 1
Step 1: Unpack and Inspect Perfect Voice Pinnacle Tis32.......................................................... 2
Step 2: Install BSIS Card ............................................................................................................. 2
Step 3: Program Strata CTX........................................................................................................ 3
Program 200: Station Data Assignment..................................................................................................................3
Program 204............................................................................................................................................................3
Program 209: Hunt Groups.....................................................................................................................................4
Program 218: Station Hunt Assignments ................................................................................................................4
System Programming for SMDI (Programs 579, 580, 803, 804) ............................................................................4
Step 4: Shut Down Strata CTX .................................................................................................... 5
Step 5: Install Perfect Voice Pinnacle Tis32 ................................................................................ 6
1. Locate the proper slot for Tis32. ........................................................................................................................6
I&M
2. Install Perfect Voice Pinnacle Tis32 according to the following steps. ..............................................................8
Step 6: Connect Tis32 Network Port to Strata CTX..................................................................... 9
Step 7: Restart Strata CTX and Verify Perfect Voice Pinnacle Tis32 Is Functioning Properly .... 9
Step 8: Connect to Perfect Voice Pinnacle Tis32 Admin Using NetMeeting ............................. 10
If using Static IP Address (out-of-box default) ......................................................................................................10
?
If using DHCP .......................................................................................................................................................10
Step 9: Configuring the System .................................................................................................11

Installation
1


1 - Introduction
Perfect Voice Pinnacle Tis32 is an integrated voice messaging and call routing system designed to
work with Toshiba Strata® CTX telephone systems. Perfect Voice Pinnacle Tis32 is packaged
entirely on a printed circuit board that resides in the host KSU. The architecture of the system
permits Perfect Voice Pinnacle Tis32 to be connected directly to the CTX system data bus. This
enables Perfect Voice Pinnacle Tis32 connectivity without the traditional analog interfaces necessary
for other voice processing systems. This means that no RSTU card is needed for Perfect Voice
Pinnacle Tis32.
System installation and initial configuration involves plugging in Perfect Voice Pinnacle Tis32 to an
available card slot in the CTX system. With the use of NetMeeting, Perfect Voice Pinnacle Tis32 can
be configured and maintained easily by using the graphical administration interface.

2 - Installation
This section provides the steps to install the Perfect Voice Pinnacle Tis32 hardware. For information
I&M
on configuring the system (creating mailboxes, classes of service, etc.), refer to the Perfect Voice
Pinnacle Installation & Maintenance Manual.
Installer Requirements
?
The installer plays a key role in the successful installation of the voice processing hardware and
software. In addition to performing the actual work of installing the product, the installer acts as a
liaison between the customer, telecommunications companies, and Teleco Technical Support. An
installer is required to have skills and experience in at least the basics of telephony and computer
technology, including the following:
Perfect Voice Pinnacle Technical training certification.
Training and experience in at least the general concepts of telecommunications.
Certified on the Toshiba Strata® CTX telephone system.
The ability to properly configure, install and remove circuit boards in a personal computer.
Required Materials
Anti-static wrist strap
BSIS card and serial cable

Installation Overview
Step 1: Unpack and Inspect Perfect Voice Pinnacle Tis32, page 2
Step 2: Install BSIS Card, page 2
Step 3: Program Strata CTX, page 3
Step 4: Shut Down Strata CTX, page 5
Step 5: Install Perfect Voice Pinnacle Tis32, page 6
Step 6: Connect Tis32 Network Port to Strata CTX, page 9
Step 7: Restart Strata CTX and Verify Perfect Voice Pinnacle Tis32 Is Functioning Properly, page 9
Perfect Voice Pinnacle Tis32

Release 1.6

April,
2003


Rev 1.1


2
Installation

Step 8: Connect to Perfect Voice Pinnacle Tis32 Admin Using NetMeeting, page 10
Step 9: Configuring the System, page 11

Step 1: Unpack and Inspect Perfect Voice Pinnacle Tis32
Before unpacking, make certain that none of the shipping containers were damaged during shipment.
Do not open any damaged shipping containers. Contact your shipping agent for appropriate claims.

WARNING: The battery on the Tis32 baseboard cannot be replaced in the field. Replacement of the
battery with an incorrect type creates the risk of explosion.

CAUTION
To ensure that the unit is not damaged during installation or maintenance, follow these precautions.
Damage may not always be immediately evident (e.g., no physical damage on the outside of the unit)
and system failure may result weeks or months later.
Handle Tis32 with care. Mechanical shock from dropping, shaking, excessive force when
seating the board into the slot, rocking a connector on or other activities can severely
I&M
damage the disk assembly or the disk's printed circuit board.
Wear an anti-static wrist strap. It can also be re-used and left with the Strata CTX cabinet.
An electrostatic charge from your body can damage the drive or circuitry permanently.
Hold Tis32 by the edges or the knob on the control panel and never touch the board's
?
surface. Pressure on the printed circuit board or contaminants from your hands (e.g., skin
oil, food particles, hand lotion) can cause component failure.
Step 2: Install BSIS Card
N o t e
TPI is required for Tis32. A BSIS card must be installed in the Strata CTX.

Install and program serial card BSIS in the Strata CTX. The serial cable will be used to connect the
BSIS card to the Pinnacle Tis32.

Release 1.6

Perfect Voice Pinnacle Tis32
April, 2003
Rev. 1.1

Installation
3


Step 3: Program Strata CTX
To the Strata CTX processor, the Perfect Voice Pinnacle Tis32 functions as one or two digital station
cards, each supporting up to 16 voice ports (BDKU). Although there are some special program
settings required for Tis32, the Strata CTX should be programmed just as it would for any external
voice mail system.
The following items can be programmed using the CTX WinAdmin program software or phone
programming command set. Refer to Strata CTX I&M Manual and Strata CTX Programming
Manual.
Program 100
Program 200: Station Data Assignment
Program 204
Program Station Hunting (Programs 209 and 218)
System Programming for SMDI (Programs 579, 580, 804, 803)

Program 100
Set cabinet slot PCB type to "BDKU/BDKS 16 DKTs without Spkr OCA".
I&M
Program 200: Station Data Assignment
Assign stations to the slot and assign as voice mail. For example, 200~215 (for 16 ports). Set
"Display DN" as the pilot number of the Voice Mail Hunt Group. This value should be the same as
?
"Number to Display" in Program 209 (see below).

Setting for Voice Mail Ports
Setting for Station Ports
02 Station Type
DKT DKT
03 Circuit Type
Voice mail
Extension
Enter Pilot DN for the VM Hunt
15 Display DN
Set to match station Prime DN
Group1
Leave this field Blank; do not enter
19 VMID Code
Set to match station Prime DN
anything!
22 MW to VM
Leave this field Blank; do not enter
Enter Pilot DN for the VM Hunt
Port
anything!
Group1
1. Programs 200:15 (for voice mail ports), 200:22 (for station ports), 209:02, 209:04, 579:10, and
579:16 should all use the same Pilot Number.
Program 204
Copy the changes to all voice mail stations.
02 Key Strip Pattern
Set to Pattern 3.
05 Tone First / Voice First
Set to Tone First
21 Adapter
Set to BPCI
19 Continuous DTMF
Set "Continuous DTMF" to "Not Continuous"
Perfect Voice Pinnacle Tis32

Release 1.6

April,
2003


Rev 1.1


4
Installation

Program 209: Hunt Groups
Create a hunt group that includes all voice mail ports (see Note 6 on Program 579:02 for IBS
Programming)
01 Hunt Method
Distributed
02 Pilot Number
Enter the Pilot DN for the Voice Mail Hunt Group2
04 Number to Display
Enter the Pilot DN for the Voice Mail Hunt Group2
07 DHG Auto Camp-on
Enable

2. Programs 200:15 (for voice mail ports), 200:22 (for station ports), 209:02, 209:04, 579:10, and
579:16 should all use the same Pilot Number.
Program 218: Station Hunt Assignments
Add all Voice Mail Stations created in Program 200 to the Hunt Group created in Program 209

I&M
System Programming for SMDI (Programs 579, 580, 803, 804)
N o t e
Set all CTX voice mail ports as SMDI integration.
?

Program 579: System Voice Mail Data
01 DID/DNIS VMID Option
DN VMID
02 Cancellation Method for VM Auto and Access Code Cancel
03 Message Desk Number
Enable
04 Output of CLASS/ANI and
Enable
05 Calling Number Digits Sent
10
07 Auto Cancel of VM and MW Enable
Must be enabled to allow CTX Call Record
09 LCD Control of Voice Mail
Enable
and Soft Keys.
Programs 200:15 (for VM ports), 200:22
Enter Pilot
(for station ports), 209:02, 209:04, 579:10,
10 Central VM Callback
DN
and 579:16 should all use the same Pilot
Number
Programs 200:15 (for VM ports), 200:22
Enter Pilot
(for station ports), 209:02, 209:04, 579:10,
16 Transfer Direct to VM DN
DN
and 579:16 should all use the same Pilot
Number
17 Length of VM ID
10

Release 1.6

Perfect Voice Pinnacle Tis32
April, 2003
Rev. 1.1

Installation
5


Program 580: Voice Mail Port Data
01 Control Method
Select SMDI
02 Send A/D Tone
Enable
04 End-to-End
Enable

Program 803: SMDI Port Assignments
00 Logical Device Number
Select 300 SMDI #0
01 Device Connection
RS232
02 Device Port Number
Select the Port configured in Program 804:00

Program 804: Voice Mail Port Data
I&M
Select port to use for SMDI (1~4), use this in Program
00 BSIS Port Number
803:02
01 Port Speed
1200
02 Port Parity
Even
?
03 Data Bits
7 Bits
04 Flow Control
None
05 Wait Timer
1


Step 4: Shut Down Strata CTX
Turn off the main power switch to the Strata CTX system.

Perfect Voice Pinnacle Tis32

Release 1.6

April,
2003


Rev 1.1


6
Installation

Step 5: Install Perfect Voice Pinnacle Tis32
1. Locate the proper slot for Tis32.
If there is not an available slot for Tis32, stop here. If a T1, DID or TIE line card needs to be
relocated to make room for Tis32, do so now. Make sure the necessary programming changes are
made to account for this move. Below are tables showing where Tis32 may be installed in the Strata
CTX100 or Strata CTX670 cabinets.

Strata CTX100
There are four slots (S101 to S104) in the base cabinet and four slots (S105 to S108) in the
expansion cabinet available for use by Tis32. The following figure and table gives information on
the number of ports available for installation in each slot.
If more than 16 ports are used, the Tis32 must be installed in slots S101, S105 or S107, and the
corresponding neighboring slot (S102, S106, or S108, respectively) must be left empty. This is
because Tis32 requires the time slot information that is delivered to the empty slot.

I&M
Strata CTX100 - Using 16 ports or less
S101
S102
S103
S104
S105
S106
S107
S108
May
May
May
May
May
May
May
May
?
install 16
install 16
install 16
install 16
install 16
install 16
install 16
install 16
port card
port card
port card
port card
port card
port card
port card
port card

Strata CTX100 - Using more than 16 ports
S101
S102
S103
S104
S105
S106
S107
S108
Must
Must
Must
leave
leave
leave
May
empty if
May
May
May
empty if
May
empty if
install 32
32-port
install 16
install 16
install 32
32-port
install 32
32-port
port card
card is
port card
port card
port card
card is
port card
card is
installed
installed
installed
in S101
in S105
in S107

Release 1.6

Perfect Voice Pinnacle Tis32
April, 2003
Rev. 1.1

Installation
7


Strata CTX670
Base Cabinet
The Base Cabinet has two dedicated slots used for the system processor PCBs (B101 and B102) and
eight universal slots, labeled S101 through S108 that can accommodate Tis32. All eight slots (slots
S101~S108) in the cabinet can accommodate one 16-port Tis32. If more than 16 ports are needed, a
32-port card may be installed but the neighboring slot must be left empty. This is because Tis32
requires the time slot information that is delivered to the empty slot.

Strata CTX670 Base Cabinet - Using 16 ports or less
S101
S102
S103
S104
S105
S106
S107
S108
May
May
May
May
May
May
May
May
install 16
install 16
install 16
install 16
install 16
install 16
install 16
install 16
port card
port card
port card
port card
port card
port card
port card
port card

Strata CTX670 Base Cabinet - Using more than 16 ports
S101
S102
S103
S104
S105
S106
S107
S108
I&M
Must
Must
Must
Must
leave
leave
leave
leave
May
empty if
May
empty if
May
empty if
May
empty if
install 32
32-port
install 32
32-port
install 32
32-port
install 32
32-port
?
port card
card is
port card
card is
port card
card is
port card
card is
installed
installed
installed
installed
in S101
in S103
in S105
in S107

Expansion Cabinets
The first six slots (slots S_01 to S_06) in the Strata CTX670 expansion cabinet can accommodate a
16-port Tis32. If more than 16 ports are needed, a 32-port card may be installed but the neighboring
slot must be left empty. This is because Tis32 requires the time slot information that is delivered to
the empty slot. (To help protect against Strata CTX configuration errors, the physical profile of the
32-port Tis32 extends into the adjacent CTX card slot.)
The next two slots (slots S_07 to S_08) in the cabinet can only accommodate a 16-port Tis32 card
that is configured eight ports. Slots S_09 and S_10 cannot be used.

Strata CTX670 Expansion Cabinet - Using 16 ports or less
S_01
S_02
S_03
S_04
S_05
S_06
S_07
S_08
S_09 S_10
May install May install
May
May
May
May
May
May
16 port
16 port
Can't Can't
install
install
install
install
install
install
card
card
be
be
16 port 16 port 16 port 16 port 16 port 16 port configured configured used used
card
card
card
card
card
card
for 8 ports
for 8 ports

Perfect Voice Pinnacle Tis32

Release 1.6

April,
2003


Rev 1.1


8
Installation

Strata CTX670 Expansion Cabinet - Using more than 16 ports

S_01
S_02
S_03
S_04
S_05
S_06
Must leave
Must leave
Must leave empty
May install
May install
empty if 32-port
empty if 32-port
May install
if 32-port card is
32-port
32-port
card is installed
card is installed
32-port card
installed in S_05
card
card
in S_01
in S_03

S_07
S_08
S_09
S_10
May install 16-port card
May install 16-port card
Can't be
Can't be
configured for 8 ports
configured for 8 ports
used
used

2. Install Perfect Voice Pinnacle Tis32 according to the following steps.

N O T E
Allow Tis32 to sit at room temperature for at least 3 hours before applying any
I&M
power. Shipping can expose Tis32 to temperature extremes. Let Tis32 adjust to room
temperature to avoid any possible damage from condensation, etc.

?
Remove Tis32 from its protective package. Remember to handle the Tis32 card with care.
Wear an anti-static wrist strap and hold the card by its edges.
Move the battery jumper to the ON position.
OFF
ON
Gently pul the
jumper off...
...and place it over the
two pins next to ON.
OFF
ON

Insert the Tis32 PCB into the appropriate slot and apply firm, even pressure to ensure proper
connection. CAUTION: Do not insert the board too slowly and make sure the board is
pushed all the way in or the key system may behave in an unexpected manner. In most cases,
however, this behavior will correct itself within a couple of minutes.
After installing, gently pull the card outward. You should feel a slight resistance. If you don't
feel the resistance, apply pressure again.
Release 1.6

Perfect Voice Pinnacle Tis32
April, 2003
Rev. 1.1

Installation
9


Step 6: Connect Tis32 Network Port to Strata CTX
Tis32 uses a static IP address (192.168.254.252) as the default for its network setting that matches
the Strata CTX's default. Even if using a static IP, the Tis32 must be properly configured for the
network it is being installed in. Check and/or change the IP address, default gateway and
SubnetMask settings. The Tis32 Network port is equipped with a 10/100BaseT Ethernet connection.
This port is used to connect Tis32 to the Local Area Network (LAN) for Unified Messaging and TPI.
The LAN connection can also be used to communicate with a separate Windows computer using
CTX WinAdmin and / or NetMeeting to access the Perfect Voice Pinnacle administration interface.
A straight through network cable used with a network hub is required. This is because of the need to
connect to the Strata CTX for TPI and the end-users network for e-mail connectivity.


Straight-pinned, 8-wire Modular Cord

Strata CTX
Pin




Pin


1
TD+
BD+ 1

ACTU or BBCU
2 TD-


RD
2


Processor
3
RD+
TD+ 3


6
RD-
TD-
6

I&M


Network Interface RJ45 Jack





Pinnacle Tis32

?

Voice Mail System

TPI Link to BSIS

LAN
Straight-pinned, 8-wire Modular Cord
or

NIC
HUB

LCD Soft Key Link


PC
Strata CTX
WinAdmin and/or

NetMeeting
Straight-pinned, 8-wire Modular Cord

NIC
Network Interface RJ45 Jack

Step 7: Restart Strata CTX and Verify Perfect Voice Pinnacle Tis32 Is
Functioning Properly
Each Tis32 has been preprogrammed at the factory for out-of-box operation on the Strata CTX. This
includes the integration and configuration parameters, and company greeting and instructions.
Turn on the main power switch to the Strata CTX system. Let it proceed without any action
from you. The Power LED should turn green when the system is operational.
Dial the extension number for each port. Tis32 should (for each port) answer and play the
default company greeting ("Thank you for calling...").
Perfect Voice Pinnacle Tis32

Release 1.6

April,
2003


Rev 1.1


10
Installation

Step 8: Connect to Perfect Voice Pinnacle Tis32 Admin Using
NetMeeting
By default, the Perfect Voice Pinnacle Tis32 is shipped with a static IP address set to
192.168.254.252. The address may be changed if necessary. If the network is set up with a DHCP
server, refer to "Setting up DHCP" below.
If using Static IP Address (out-of-box default)
N O T E
In order to connect to the Perfect Voice Pinnacle Tis32, the IP address of the
Admin PC needs to be changed. Teleco recommends changing it to
192.168.254.251.

To start NetMeeting (Static IP Address):
Click Programs > Accessories > Communications > NetMeeting
In the NetMeeting program, click Tools > Options > Security
Under Outgoing Calls, select "I prefer to make secure outgoing calls."
Under Certificate, select "Use privacy (Encryption) only" then click OK.
I&M
Click the telephone icon. The Place a Call box is displayed.
In the To field, type Perfect Voice Pinnacle Tis32's IP Address (192.168.254.252 is the
default). When prompted enter the user name and password. (The default user name is
"Administrator" and the default password is "Administrator".) Leave the Domain field
?
blank. This completes the connection between Tis32 and the Admin PC using NetMeeting.
To start the system administration interface, double-click the Admin icon and log into
Perfect Voice Pinnacle Admin.
If using DHCP
Since Perfect Voice Pinnacle Tis32 uses a static IP address by default, the following steps must be
performed to set-up the system for DHCP.
Setting Up DHCP (while connected with NetMeeting via static IP address)
Right-click Network Neighborhood, Select Properties
Select Protocols, select TCP/IP
Click Properties
Check "Obtain IP address automatically"

To start NetMeeting (DHCP):
Click Programs > Accessories > Communications > NetMeeting
Click the telephone icon. The Place a Call box is displayed.
Enter the computer name (The default computer name is Pinnacle-Tis32).
When prompted enter the user name and password. (The default user name is
"Administrator" and the default password is " Administrator ".) Leave the Domain field
blank. This completes the connection between Tis32 and the Admin PC using NetMeeting.
To start the system administration interface, double-click the Admin icon and log into
Perfect Voice Pinnacle Admin.

Release 1.6

Perfect Voice Pinnacle Tis32
April, 2003
Rev. 1.1

Installation
11


Step 9: Configuring the System
For information on configuring the system (creating mailboxes, classes of service, etc.), refer to the
Perfect Voice Pinnacle Installation & Maintenance Manual.


I&M
?
Perfect Voice Pinnacle Tis32

Release 1.6

April,
2003


Rev 1.1