Multiline Terminal
Conference Bridge





Table of Contents
Chapter 1 Introduction
Section 1
What is the Multiline Conference Bridge ............. 1-1
Chapter 2 Setting up the Multiline Conference Feature
Section 1
Setup Procedures ............................................... 2-1
Section 2
Operating Procedures ......................................... 2-2
Section 3
Setup Conditions................................................. 2-3
Chapter 3 Installing the CNF(8)-U10 ETU
Section 1
Description .......................................................... 3-1
Section 2
Installation ........................................................... 3-1
Section 3
Switch Settings ................................................... 3-3
Section 4
LED Indications ................................................... 3-4
Section 5
Connectors.......................................................... 3-4
Multiline Terminal Conference Bridge Installation Guide
i

Introduction

SECTION 1
WHAT IS THE MULTILINE CONFERENCE BRIDGE
The Multiline Conference Bridge provides a feature of the
Electra Elite 48 and 192 systems that allows any intercom
user or any outside party calling to a port of the CNF(8)-U10
ETU to enter a multiparty conference call. The CNF(8)-U10
ETU supports one 8-party conference or two 4-party
conferences controlled by a switch setting. DSP based
amplification provides a higher quality conference call.
This feature is available for all Electra Elite Multiline Terminals
and requires that the CNF(8)-U10 ETU be installed in the
Electra Elite KSU.
Two CNF(8)-U10 ETUs may be installed in the Electra Elite
system.
Multiline Terminal Conference Bridge Installation Guide
1 - 1

Setting up the Multiline
Conference Feature

SECTION 1
SETUP PROCEDURES
Before using the Multiline Conference Bridge feature
passwords must be assigned. The System Administrator
should perform these procedures.
To set the supervisor password:
1.
Call a CNF(8)-U10 ETU extension, and wait for the voice
prompt.
2.
Dial the default Supervisor Password (),
then .
3.
Follow the voice prompt, and enter the setting
verification mode (). Then enter system set mode.
4.
Follow the voice prompt to change Supervisor Password
(4~8 digits).
To set the conference 1 and/or conference 2 passwords:
1.
Call a CNF(8)-U10 ETU extension, and wait for the voice
prompt.
2.
Dial the default Supervisor Password (),
then .
3.
Skip the steps until the Conference Setup mode is
available for conference 1 or conference 2.
4.
Follow the voice prompt, and set the conference 1 or the
conference 2 password (4~8 digits).
Multiline Terminal Conference Bridge Installation Guide
2 - 1

Issue 1
NEC America, Inc.
To record new customized greeting:
1.
Call a CNF(8)-U10 ETU extension, and wait for the voice
prompt.
2.
Dial the default Supervisor Password (),
then .
3.
Skip options until Customized Greeting option is selected.
4.
Follow the voice prompt and record a new Customized
Greeting.
SECTION 2
Operating Procedures
To perform the various functions associated with this feature,
use the following procedures.
To start/enter a conference call from an internal extension:
1.
Call a CNF(8)-U10 extension.
2.
When the voice prompt is heard, enter the conference
bridge 1 or 2 password, and press .
3.
Start the conference call.
To start/enter a conference call from an outside DID call:
1.
Call the DID number assigned to the conference bridge.
2.
When the voice prompt is heard, enter the conference
bridge 1 or 2 password, and press .
3.
Start the conference call.
To start a conference call from an outside DIT call:
1.
Call a trunk that is set as DIT to the conference bridge.
2.
When the voice prompt is heard, enter the conference
bridge 1 or 2 password and press .
3.
Start the conference call.
2 - 2
Setting up the Multiline Conference Feature

NEC America, Inc.
Issue 1
To start a conference call from an incoming CO call using
an Automated Attendant:
1.
Call a trunk that is assigned to the Automated Attendant.
2.
Select the option/extension for a multiline conference
call.
3.
When the voice prompt is heard, enter the conference
bridge 1 or 2 password and press .
4.
Start the conference call.
To start a conference call from an incoming CO call using
an Attendant:
1.
Call the attendant, and ask to be transferred to an
extension connected to the conference bridge.
2.
Wait until the transfer is complete.
3.
When the voice prompt is heard, enter the conference
bridge 1 or 2 password, and press .
4.
Start the conference call.
SECTION 3
SETUP CONDITIONS
Data Assignment:

Assign the CNF(8)-10 ETU as SLI(8)-U10 ETU using
Memory Block 7-1 (Card Interface Slot Assignment).

All ports that are set to the same conference group
should be set to the same Master Hunt Group using
Memory Blocks 4-14 (Intercom Master Hunt Number
Selection) and 4-15 (Intercom Master Hunt Number
Forward Assignment).

When CNF is set for two, 4-party conferences, ports
1~4 should be set to the same Master Hunt Group, and
ports 5~8 should be set to a different Master Hunt
Group.
Multiline Terminal Conference Bridge Installation Guide
2 - 3

Issue 1
NEC America, Inc.

DIT assignment may be set to Master Hunt Group using
Memory Blocks 3-42 (DIT Assignment) for day or 3-43
(ANA Assignment) for night.

All ports should be assigned as a Voice Mail Port by using
Memory Block 4-35 (Voice Mail/SLT Selection) to insure
proper disconnect signals.
General

The supervisor password can be reset to 0000 (default) as
follows:
1.
Call the CNF ETU.
2.
When prompted for supervisor password, dial
(no prompts are heard at this
time).
3.
Press the Reset Switch SW1 to reboot the
CNF(8)-U10 ETU.
2 - 4
Setting up the Multiline Conference Feature

Installing the
CNF(8)-U10 ETU

SECTION 1
DESCRIPTION
Refer to Figure 3-1 CNF(8)-U10 ETU.
The Multiline Conference Bridge allows any intercom user and
any outside party calling to a port of the CNF(8)-U10 ETU to
enter a multiparty Conference Call.
Each CNF(8)-U10 ETU supports one 8-party conference or
two 4-party conferences controlled by switch SW3-1 on the
ETU.
SECTION 2
INSTALLATION
This ETU is installed in:

Slots S1~S8 in the B64-U10 KSU for Electra Elite
192.

Slots S2~S7 in the B48-U10 KSU for Electra Elite 48.
Multiline Terminal Conference Bridge Installation Guide
3 - 1

Issue 1
NEC America, Inc.

Figure 3-1 CNF(8)-U10 ETU
3 - 2
Installing the CNF(8)-U10 ETU

NEC America, Inc.
Issue 1
SECTION 3
SWITCH SETTINGS

Table 3-1 CNF(8)-U10 ETU Reset Switches
Switch
Setting
Description
SW2
Press to Reset
Host Reset Switch

Table 3-2 CNF(8)-U10 ETU Maximum Conference Time Switch
Maximum Conference
Switch
Setting
Time
SW3
SW3-2 SW3-3
ON ON
1 Hour
ON OFF
2 Hour
OFF ON
3 Hour
OFF OFF
No Limit

Table 3-3 CNF(8)-U10 ETU Party Size Switch
Switch
Setting
Description
SW3-1
ON
One 8-Party Conference
SW3-1
OFF
Two 4-Party Conferences
Multiline Terminal Conference Bridge Installation Guide
3 - 3

Issue 1
NEC America, Inc.
SECTION 4
LED INDICATIONS
Status
Flashing when active
Channels 0~7
Channel Busy Status
SECTION 5
CONNECTORS
This ETU has three connectors:

J1
Connects to the backboard

J2
Not currently used

J3
Nine-pin RS-232C connector for maintenance
3 - 4
Installing the CNF(8)-U10 ETU

Multiline Terminal
Conference Bridge




Document Outline